The Geyserwise TSE, brought to you by The Water Solar Company, is a versatile and efficient control system designed for use in both Close Coupled Solar Geyser Systems and Standard Geyser Systems. Offering a range of features, this device serves as a reliable geyser timer and a timer on a thermosyphon solar system, providing enhanced control and monitoring capabilities.
Geyserwise TSE Key Features:
1. Dual System Compatibility: Ideal for use in Close Coupled Solar Geyser Systems and Standard Geyser Systems, offering flexibility in application.
2. Clear Display: The intuitive display provides real-time information on water temperature, time, day, heating mode, and any malfunction conditions, ensuring easy monitoring and control of your solar water heating system.
3. Heating Modes: Choose between auto or manual heating modes, allowing users to customize the operation based on preferences and requirements.
4. Temperature Settings: Easily set the desired water temperature within the range of 30 – 75°C, with four different temperature settings available. The factory default is set at 55°C.
5. Programmable Timer: A daily programmable timer with four time settings enhances control over the system, optimizing energy usage based on your daily routine.
6. Error Conditions Alert: The system alerts users to error conditions through warning codes (E2 to E5 and E7), facilitating quick identification and resolution of issues.
7. Electronic Thermostat with Thermal Cut-Out: The Geyserwise TSE incorporates an electronic thermostat with a mechanical thermal cut-out at 90°C, providing an additional layer of safety. Note: Adjust cut-out temperature for systems expecting temperatures above this threshold.
Geyserwise TSE Specifications
Geyserwise TSE Technical Parameters:
- Operating Voltage: 230VAC / 50HZ.
- Main Relay Contact Rating: 30AMP (Max 4KW).
- Operating Voltage Range: 220V – 250V AC.
- Temperature Display Range: 0 – 99°C (“-5” when below -5°C, “EA” when above 99°C).
- High Temperature Warning: Above 84°C.
- Temperature Setting Ranges: 30 – 75°C (for electric water heating).
- Heat Failure Detection: Activates when the increase is at a rate of less than 4°C per hour.
- Mechanical Thermal Cut-Out: At 90°C. Adjust for systems expecting temperatures above this threshold.
- Dry Heat Detection: Alerts for an empty cylinder.
- Temperature Tolerance: ± 2%.
- Temperature Differential Setting: 1°C.
- Switching Differential: 6°C.
- Temperature Probe Failure Detection: For the tank.
- Temperature Probe Range: -30 to + 130°C.